This means that the fire Alarms should ideally be located near all potential sources of fires and that the alarm should be heard throughout the house – particularly in the bedrooms. The main reason for fitting Smoke/Heat/Multi-Sensor Alarms in dwellings is to ensure that when there is a fire, sufficient early warning is given so that everybody can escape safely. The advice here follows the guidance in British Standard BS 5839-Part 6:2013 and IS 3218:2013 in general (for further information refer to the relevant standards). (IRE) Please refer to ET101: 2008: National Rules for Electrical Installations (See BS 5839-6: 2013 for further information) (b) a separately electrically protected, regularly used local lighting circuit.Īlarms should be connected on a single final circuit, unless the means of interconnection is by radio signals (e.g. (a) an independent circuit at the dwelling’s main distribution board, in which case no other electrical equipment should be connected to this circuit (other than a dedicated monitoring device installed to indicate failure of the mains supply to the Alarms) or

ei 131 smoke alarm manual

The mains supply to the Alarms should take the form of either: The power supply for the Alarms should be derived from the public electricity supply to the dwelling. (UK) BS 5839-6: 2013 gives the following recommendations regarding the mains supply to be used in a Grade D system. The Alarm must be continuously powered 24 hours a day so it is important that it is not on a circuit that can be turned off by a switch. Do not use a high voltage insulation tester on the Alarm. The Alarm must not be connected when the house wiring insulation is being checked with high voltages.

#EI 131 SMOKE ALARM MANUAL INSTALL#

Light Dimmer Circuits – The Alarms must not be powered from a light dimmer circuit.ĭo not install Alarms in new or renovated buildings until all work is completed. This also applies to battery powered UPS (Uninterruptible Power Supply) inverters. If in doubt please check with the manufacturer of the inverter. PV solar panel, the Total Harmonic Distortion (THD) must be less than 5%. If connecting to a power source that utilises an inverter, e.g. This product is designed to be connected to a Pure or True Sine Wave 230V AC supply. There are important markings on the underside of the Alarm.Īlternative Energy Sources - (Wind, Solar, UPS etc.) The Alarm must not be exposed to dripping or splashing. Alternatively, it can be screwed to a standard junction box (BS 4662 single gang accessory box). The mounting plate can be screwed directly to the ceiling. The Alarm is designed to be permanently mounted, using its own built-in terminal block to connect it to the mains. Failure to install this Alarm correctly may expose the user to shock or fire hazards and damage the product. Mains operated Alarms should be installed and interconnected by a qualified electrician in accordance with the local appropriate Regulations for Electrical Installations. For more information on using this feature, please refer to the relevant section on or 2.1 Important Safety Instructions

#EI 131 SMOKE ALARM MANUAL DOWNLOAD#

This feature allows the user to download information from the Alarm through the use of a mobile App.

ei 131 smoke alarm manual

#EI 131 SMOKE ALARM MANUAL SERIES#

The Ei3000 series Alarms are AudioLINK enabled.

ei 131 smoke alarm manual

Each Alarm comes with built-in rechargeable backup batteries to power the Alarm in the event of a mains failure. The mains and battery power is automatically connected as the Alarm slides onto the mounting plate. The Ei3000 series is supplied with a mounting plate that allows very quick and simple installation of the Alarm. It can be a hardwired interconnection, a wireless interconnection or a mixture of both (for the wireless option an Ei3000MRF SmartLINK module needs to be added to each Alarm – sold separately). Up to 12 Alarms can be interconnected so that if one senses fire, all Alarms sound. places where Smoke Alarms cannot be installed without the risk of excessive nuisance alarms. It is ideal for kitchens, garages, boiler houses and other areas where there are normally high levels of fumes, smoke or dust i.e. interconnected with Ei Electronics mains powered Multi-Sensor Fire or Smoke Alarms. It can only to be used as part of a fire detection system, i.e. The Ei3014 is a Heat Alarm with a Class A1 heat detection sensor.

ei 131 smoke alarm manual

It is ideal for hallway, landing and living room areas. The Ei3016 is an Optical Smoke Alarm, with a proven optical sensor and automatic dust compensation delivering a fast response to smouldering fires. It detects both smoke and heat from a fire and is ideal for hallway, landing, living room and bedroom areas. The Ei3024 is a Multi-Sensor Fire Alarm with heat enhanced optical smoke sensor and automatic dust compensation, delivering a faster response to a wider range of fires.